Maintenance Spo2 sensor
How to Identify Spo2 Tech Of GE Patient monitor?
How do I disinfect reusable SpO2 probes of szmedplus?
How do I stock SpO2 probes and Adapter/Extension cables?
What is the max. length of SpO2 probes?
Spo2 Sensors Difference exist
How to test Spo2 sensor?
Multi-scenario Application Of Spo2 Sensor in Medical Field
How often SpO2 reposition?
What's normal Spo2?
What's Spo2?
How to choose Spo2 sensor?
Why 10 Lead EKG Called 12 lead
GE Spo2 probe-differ module
ECG Color coding
ETCO2 Monitored Indications
Guide to put Electrode
What's ECG?
Digital&Analog spo2 sensor
Principle Of Measuring ETCO2
ow to use neonatal blood oxygen probe for blood oxygen saturation monitoring
szmedplus Tells You What You Must Know About The Electrocardiogram
Four considerations for choosing a Spo2 sensor (spo2 probe)
The Role And Principle Of Spo2 Sensor
What Is A Holter Cable
Influence Of Blood Pressure Cuff Size On Accuracy Of Blood Pressure Readings
Philips Reusable Spo2 Sensor Instructions
Introduction Of Nihon Kohden Blood Oxygen Technology
DS100A Nellcore Adult SpO2 Sensor Reusable Instructions
How To Clean A Repetitive SpO2 Probe
Which Finger Should The Blood Oxygen Sensor Be Placed On
Pros and cons of invasive blood pressure
LEMO Medical Push-Pull Connectors
How To Use And Maintain ECG Lead Wires Correctly
Can The Finger Clip Oximetry Probe Be Used in The Ear?
EKG Cable Science Knowledge
Clinical significance of disposable temperature probe

How to choose Spo2 sensor? 

Consideration when choosing Spo2 Sensor
·  There are some general guidelines to choosing the right sensor. The ideal application site has good perfusion, does not generate movement artifact, is comfortable for the patient and allows easy application. Most sensors work on extremities such as a finger, toe or ear.
·  The size of the application site determines what size sensor to use. The age of the patient is not a factor.
·  If a sensor is too big or too small, the light emitting diode and the light detector may not line up. This could cause a false reading or an alarm.
·  If a finger sensor is too large, it may slip partway off so that the light source partly
covers the finger. This condition, called optical bypass, causes incorrect readings.
·  If a finger is inserted too far into the sensor it may be squeezed by the sensor, which
causes venous pulsation. The pulse oximeter recognizes arterial blood only by its pulsing motion, so in this case it also measures venous blood. This causes readings which are falsely low.