Maintenance Spo2 sensor
How to Identify Spo2 Tech Of GE Patient monitor?
How do I disinfect reusable SpO2 probes of szmedplus?
How do I stock SpO2 probes and Adapter/Extension cables?
What is the max. length of SpO2 probes?
Spo2 Sensors Difference exist
How to test Spo2 sensor?
Multi-scenario Application Of Spo2 Sensor in Medical Field
How often SpO2 reposition?
What's normal Spo2?
What's Spo2?
How to choose Spo2 sensor?
Why 10 Lead EKG Called 12 lead
GE Spo2 probe-differ module
ECG Color coding
ETCO2 Monitored Indications
Guide to put Electrode
What's ECG?
Digital&Analog spo2 sensor
Principle Of Measuring ETCO2
ow to use neonatal blood oxygen probe for blood oxygen saturation monitoring
szmedplus Tells You What You Must Know About The Electrocardiogram
Four considerations for choosing a Spo2 sensor (spo2 probe)
The Role And Principle Of Spo2 Sensor
What Is A Holter Cable
Influence Of Blood Pressure Cuff Size On Accuracy Of Blood Pressure Readings
Philips Reusable Spo2 Sensor Instructions
Introduction Of Nihon Kohden Blood Oxygen Technology
DS100A Nellcore Adult SpO2 Sensor Reusable Instructions
How To Clean A Repetitive SpO2 Probe
Which Finger Should The Blood Oxygen Sensor Be Placed On
Pros and cons of invasive blood pressure
LEMO Medical Push-Pull Connectors
How To Use And Maintain ECG Lead Wires Correctly
Can The Finger Clip Oximetry Probe Be Used in The Ear?
EKG Cable Science Knowledge
Clinical significance of disposable temperature probe

ETCO2 Monitored Indications 

End-tidal CO2 concentration or partial pressure (ETCO2) monitoring can reflect lung ventilation, as well as pulmonary blood flow. When there is no obvious cardiopulmonary disease and the V/Q ratio is normal. ETCO2 can reflect PaCO2 (arterial blood carbon dioxide). Normal ETCO2 is 5% which is equivalent to 5KPa (38mmHg).

 

1. The safe application of anesthesia machine and ventilator.

2. Various types of respiratory insufficiency.

3. Cardiopulmonary resuscitation.

4. Severe shock.

5. Heart failure and pulmonary infarction.

6. Determine the position of the endotracheal tube in general anesthesia.

 

Clinical evaluation When using a ventilator and anesthesia, adjust the ventilation volume according to the ETCO2 measurement to keep the ETCO2 close to the preoperative level. Monitoring and its waveform can also determine whether the tracheal tube is in the airway. For those who are undergoing mechanical ventilation, such as air leakage, catheter twisting, tracheal obstruction, etc., the ETCO2 number and shape change and alarm can be immediately detected and handled in time. Continuous monitoring provides a basis for safe evacuation of mechanical ventilation. However, malignant hyperthermia, elevated body temperature, and a large amount of intravenous injection of NaHCO3 can increase CO2 production, increase ETCO2, and increase the amplitude. In shock, cardiac arrest, and pulmonary air embolism or thrombotic infarction, reduction of pulmonary blood flow can make CO2 depth drop rapidly To zero. ETCO2 also helps to judge the effectiveness of cardiopulmonary resuscitation. If ETCO2 is too low, factors such as hyperventilation should be ruled out.