Maintenance Spo2 sensor
How to Identify Spo2 Tech Of GE Patient monitor?
How do I disinfect reusable SpO2 probes of szmedplus?
How do I stock SpO2 probes and Adapter/Extension cables?
What is the max. length of SpO2 probes?
Spo2 Sensors Difference exist
How to test Spo2 sensor?
Multi-scenario Application Of Spo2 Sensor in Medical Field
How often SpO2 reposition?
What's normal Spo2?
What's Spo2?
How to choose Spo2 sensor?
Why 10 Lead EKG Called 12 lead
GE Spo2 probe-differ module
ECG Color coding
ETCO2 Monitored Indications
Guide to put Electrode
What's ECG?
Digital&Analog spo2 sensor
Principle Of Measuring ETCO2
ow to use neonatal blood oxygen probe for blood oxygen saturation monitoring
szmedplus Tells You What You Must Know About The Electrocardiogram
Four considerations for choosing a Spo2 sensor (spo2 probe)
The Role And Principle Of Spo2 Sensor
What Is A Holter Cable
Influence Of Blood Pressure Cuff Size On Accuracy Of Blood Pressure Readings
Philips Reusable Spo2 Sensor Instructions
Introduction Of Nihon Kohden Blood Oxygen Technology
DS100A Nellcore Adult SpO2 Sensor Reusable Instructions
How To Clean A Repetitive SpO2 Probe
Which Finger Should The Blood Oxygen Sensor Be Placed On
Pros and cons of invasive blood pressure
LEMO Medical Push-Pull Connectors
How To Use And Maintain ECG Lead Wires Correctly
Can The Finger Clip Oximetry Probe Be Used in The Ear?
EKG Cable Science Knowledge
Clinical significance of disposable temperature probe

EKG Cable Science Knowledge 

The use of each lead of the ECG lead wire

 

ECG AND LEAD WIRES ARE DIVIDED INTO FIVE COLORS: RED, YELLOW, GREEN, BLACK, AND WHITE, AND WHITE IS DIVIDED INTO C  1. C 2. C 3. C 4. C 5 C6 HAS A TOTAL OF 10 WIRES.

 

 

RED IS CONNECTED TO THE RIGHT UPPER LIMB, YELLOW IS CONNECTED TO THE LEFT UPPER LIMB, GREEN IS CONNECTED TO THE LEFT LOWER LIMB, BLACK IS CONNECTED TO THE RIGHT LOWER LIMB, AND EACH LEAD OF THE WHITE LEAD LINE IS CONNECTED TO THE CORRESPONDING LEAD IN THE CHEST. THE SPECIFIC PLACEMENT IS AS FOLLOWS:

First

Limb lead: Limb lead Ⅰ The right upper limb is connected to the negative pole, and the left upper limb is connected to the positive pole. Limb lead II is connected to the negative pole in the right upper limb and the positive pole in the left lower limb.

 

 

Second

Limb lead III is connected to the negative pole in the left upper limb and the positive pole in the left lower limb. The pressurized unipolar limb lead aVR is connected to the positive pole in the right upper limb, and the negative pole is connected to the left upper limb and the left lower limb.

 

Third

The pressurized unipolar limb lead aVL, the left upper limb is connected to the positive pole, and the right upper limb and the left lower limb are connected to the negative pole. The pressurized unipolar limb lead aVF, the left lower limb is connected to the positive pole, and the left upper limb and the right upper limb are connected to the negative pole.

 

 

Fourth

  • Chest leads: V1 is placed in the 4th space on the right sternal border; 

  • V2 is in the 4th intercostal space on the left border of the sternum, opposite to V1; 

  • V3 is at the midpoint of the connecting line between V2 and V4; 

  • V4 is on the left The fifth intercostal midclavicular line is under the nipple; 

  • V5 is the left anterior axillary line at the same level as V4; 

  • V6 is the left midaxillary line at the same level as V4 and V5; 

  • V7 is at the left posterior axillary line, at the same level as V4 and V5 Horizontal plane; 

  • V8 is on the left subscapular angle, the same horizontal plane as V4, V5, V6, and V7; 

  • V9 is on the same horizontal plane as V4, V5, and V6 next to the left clavicle; 

  • V3R, V4R, V5R are on the right side of the corresponding parts of V3, V4, and V5. 

  • Side chest, one on the left and one on the right.

 